Governed assumptions register

Every constant, correlation coefficient and design limit the calculation engine uses. Owned, versioned and identical for every engineer.

This is the register that replaces the constants buried in individual spreadsheet cells. A value here has an owner, a basis, an allowed range and a revision number. Changing one updates every design that depends on it, and every issued document records which revision it used, so a calculation from two years ago can still be reproduced exactly. Entries drawn directly from a published standard are locked.

Choke model13 entries

AssumptionValue UnitAllowed range RevOwnerBasis
Gilbert coefficient A
CHOKE_GILBERT_A
10 - — 1 Testing Engineering Gilbert (1954), API 14B practice
rationale
Baseline multiphase critical-flow correlation. Default for Middle East light/medium crude.
locked — published standard
Gilbert exponent B (GLR)
CHOKE_GILBERT_B
0.546 - — 1 Testing Engineering Gilbert (1954)
rationale
Gas-liquid ratio exponent.
locked — published standard
Gilbert exponent C (bean)
CHOKE_GILBERT_C
1.89 - — 1 Testing Engineering Gilbert (1954)
rationale
Choke diameter exponent, diameter in 1/64 in.
locked — published standard
Ros coefficient A
CHOKE_ROS_A
17.4 - — 1 Testing Engineering Ros (1960)
rationale
Alternative correlation, tends to predict larger beans.
locked — published standard
Ros exponent B (GLR)
CHOKE_ROS_B
0.5 - — 1 Testing Engineering Ros (1960) locked — published standard
Ros exponent C (bean)
CHOKE_ROS_C
2 - — 1 Testing Engineering Ros (1960) locked — published standard
Baxendell coefficient A
CHOKE_BAXENDELL_A
9.56 - — 1 Testing Engineering Baxendell (1957) locked — published standard
Baxendell exponent B (GLR)
CHOKE_BAXENDELL_B
0.546 - — 1 Testing Engineering Baxendell (1957) locked — published standard
Baxendell exponent C (bean)
CHOKE_BAXENDELL_C
1.93 - — 1 Testing Engineering Baxendell (1957) locked — published standard
Achong coefficient A
CHOKE_ACHONG_A
3.82 - — 1 Testing Engineering Achong (1961)
rationale
Derived from Lake Maracaibo wells; included for sensitivity comparison only.
locked — published standard
Achong exponent B (GLR)
CHOKE_ACHONG_B
0.65 - — 1 Testing Engineering Achong (1961) locked — published standard
Achong exponent C (bean)
CHOKE_ACHONG_C
1.88 - — 1 Testing Engineering Achong (1961) locked — published standard
Critical (sonic) pressure ratio
CRITICAL_RATIO
0.55 Pdn/Pup 0.400 – 0.600 2 Testing Engineering Isentropic choked flow, k~1.27
rationale
Below this downstream/upstream ratio the bean is in critical flow and rate is independent of downstream pressure.

Deliverability2 entries

AssumptionValue UnitAllowed range RevOwnerBasis
Vogel IPR coefficient on (Pwf/Pr)
VOGEL_A
0.2 - — 1 Reservoir Vogel (1968)
rationale
q/qmax = 1 - 0.2(Pwf/Pr) - 0.8(Pwf/Pr)^2
locked — published standard
Vogel IPR coefficient on (Pwf/Pr)^2
VOGEL_B
0.8 - — 1 Reservoir Vogel (1968) locked — published standard

Erosion5 entries

AssumptionValue UnitAllowed range RevOwnerBasis
API 14E C-factor, continuous service, solids-free
EROS_C_CONTINUOUS
100 - 60.000 – 200.000 1 Flow Assurance API RP 14E 2.5
rationale
Conservative baseline for carbon steel continuous duty.
API 14E C-factor, intermittent service
EROS_C_INTERMITTENT
125 - 60.000 – 250.000 1 Flow Assurance API RP 14E 2.5
rationale
Applicable to short-duration clean-up and flowback.
C-factor derating when sand is present
EROS_C_SAND_DERATE
0.6 fraction 0.300 – 1.000 3 Flow Assurance NESR internal ES-WT-011
rationale
Applied when produced sand exceeds the trigger concentration.
Sand concentration triggering derate
EROS_SAND_TRIGGER
1 pptb 0.100 – 10.000 2 Flow Assurance NESR internal ES-WT-011
rationale
Above 1 lb per 1000 bbl the solids-free C-factor is no longer valid.
Erosional velocity ratio caution threshold
EVR_CAUTION
0.8 - 0.500 – 1.000 1 Flow Assurance NESR internal ES-WT-011
rationale
Design target is to stay at or below 80% of the erosional velocity.

Heating5 entries

AssumptionValue UnitAllowed range RevOwnerBasis
Indirect heater thermal efficiency
HEATER_EFFICIENCY
0.8 fraction 0.600 – 0.920 1 Equipment Engineering Vendor data, glycol bath heaters
rationale
Applied to convert process duty to fired duty.
Specific heat of gas
CP_GAS
0.55 Btu/lb-degF 0.400 – 0.800 1 Process GPSA Data Book Fig. 24-7
rationale
Average over the heating range for 0.65-0.85 SG gas.
Specific heat of crude oil
CP_OIL
0.48 Btu/lb-degF 0.400 – 0.600 1 Process GPSA Data Book Sec. 23
Specific heat of produced water
CP_WATER
1 Btu/lb-degF 0.900 – 1.050 1 Process Standard
Heater duty design factor
HEATER_DESIGN_FACTOR
1.2 - 1.000 – 1.500 2 Equipment Engineering NESR internal ES-WT-006
rationale
Contingency applied to calculated duty before heater selection.

Hydrates2 entries

AssumptionValue UnitAllowed range RevOwnerBasis
Joule-Thomson cooling coefficient, gas phase
JT_COEFF
0.045 degF/psi 0.020 – 0.080 4 Flow Assurance Field-calibrated, MENA gas 0.6-0.75 SG
rationale
Used to estimate temperature downstream of the choke. Replace with EOS flash when PVT is available.
Minimum margin above hydrate formation temperature
HYDRATE_MARGIN_F
10 degF 5.000 – 25.000 2 Flow Assurance NESR internal ES-WT-004
rationale
Operating temperature must stay this far above the hydrate curve.

Pressure integrity3 entries

AssumptionValue UnitAllowed range RevOwnerBasis
Minimum margin of equipment MAWP over MASP
DESIGN_MARGIN_PCT
10 % 5.000 – 25.000 3 Well Integrity NESR internal ES-WT-002
rationale
MAWP of the weakest spread component must exceed MASP by this margin.
Site pressure test factor on MOP
TEST_PRESSURE_FACTOR
1.1 - 1.000 – 1.500 1 Well Integrity ASME B31.3 / client procedure
Fallback static gas gradient
GAS_GRAD_PSI_FT
0.08 psi/ft 0.030 – 0.150 1 Well Integrity Used only if composition is unavailable
rationale
The engine prefers the compressible column calculation.

Radiation10 entries

AssumptionValue UnitAllowed range RevOwnerBasis
Fraction of heat radiated, oil burner
RAD_F_OIL
0.2 - 0.100 – 0.400 1 HSE Engineering API STD 521 Annex C
rationale
Typical for atomised crude burners with air assist.
Fraction of heat radiated, gas flare
RAD_F_GAS
0.15 - 0.100 – 0.350 1 HSE Engineering API STD 521 Annex C
rationale
Function of gas composition and tip design.
Atmospheric transmissivity
TAU_ATM
1 - 0.700 – 1.000 1 HSE Engineering API STD 521 6.4.2
rationale
Conservative value of 1.0 used unless humidity correction is agreed with client.
Lower heating value of crude
LHV_OIL
18,300 Btu/lb 16,000.000 – 20,000.000 1 Process GPSA Data Book Sec. 23
Lower heating value of associated gas
LHV_GAS_SCF
1,050 Btu/scf 900.000 – 1,400.000 2 Process GPSA Data Book Sec. 23
rationale
Rich associated gas. Reduce for lean or N2-bearing streams.
Radiation limit, continuously manned area
K_PERSONNEL
500 Btu/hr-ft2 440.000 – 600.000 1 HSE Engineering API STD 521 Table 8 (1.58 kW/m2)
rationale
Continuous exposure with appropriate clothing.
locked — published standard
Radiation limit, escape route, few seconds exposure
K_ESCAPE
1,500 Btu/hr-ft2 1,200.000 – 1,800.000 1 HSE Engineering API STD 521 Table 8 (4.73 kW/m2) locked — published standard
Radiation limit, equipment and unmanned areas
K_EQUIPMENT
2,000 Btu/hr-ft2 1,500.000 – 3,000.000 1 HSE Engineering API STD 521 Table 8 (6.31 kW/m2) locked — published standard
Flame length correlation coefficient
FLAME_LEN_A
0.006 - — 1 HSE Engineering API STD 521 Annex C
rationale
L = A * Q^B, Q in Btu/hr, L in ft.
locked — published standard
Flame length correlation exponent
FLAME_LEN_B
0.478 - — 1 HSE Engineering API STD 521 Annex C locked — published standard

Separation5 entries

AssumptionValue UnitAllowed range RevOwnerBasis
Souders-Brown K, horizontal vessel with mist extractor
SB_K_HORIZONTAL
0.4 ft/s 0.200 – 0.600 1 Process API 12J / Arnold & Stewart
rationale
Governs maximum gas velocity before liquid carryover.
Design liquid fill fraction of separator volume
SEP_LIQUID_FILL
0.5 fraction 0.300 – 0.700 1 Process API 12J
rationale
Half-full is the standard horizontal separator design case.
Oil retention time
RETENTION_OIL_MIN
3 minutes 1.000 – 10.000 2 Process API 12J Table 1, 30-40 API crude
rationale
Increase to 5-10 min for heavy or foaming crude.
Water retention time
RETENTION_WATER_MIN
3 minutes 1.000 – 10.000 1 Process API 12J Table 1
Separator utilisation caution threshold
SEP_UTIL_CAUTION
0.85 fraction 0.600 – 1.000 1 Process NESR internal ES-WT-008
rationale
Flag when predicted load exceeds 85% of rated capacity.

Sour service3 entries

AssumptionValue UnitAllowed range RevOwnerBasis
H2S partial pressure threshold for sour service
H2S_PARTIAL_LIMIT
0.05 psia 0.050 – 0.050 1 Materials NACE MR0175 / ISO 15156-1
rationale
At or above this partial pressure, sour-rated materials are mandatory.
locked — published standard
H2S personal alarm set point
H2S_ALARM_PPM
10 ppm 5.000 – 20.000 1 HSE OSHA / client HSE case locked — published standard
H2S immediately dangerous to life or health
H2S_IDLH_PPM
100 ppm 100.000 – 100.000 1 HSE NIOSH locked — published standard